Empire Comfort Systems VFP36PP32EP-2 Owner's Manual

Browse online or download Owner's Manual for Fireplaces Empire Comfort Systems VFP36PP32EP-2. Empire Comfort Systems VFP36PP32EP-2 Owner`s manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
SEE-THROUGH FIREPLACE MODELS:
VFP36SP32EN-1
VFP36SP32EP-1
PENINSULA FIREPLACE MODELS:
VFP36PP32EN-1
VFP36PP32EP-1
U.L. FILE: MH46389
WARNING: If not installed, operated and maintained
in accordance with the manufacturer's instructions,
this product could expose you to substances in fuel or
from fuel combustion which can cause death or seri-
ous illness.
This is an unvented gas-fired heater. It uses air (oxy-
gen) from the room in which it is installed. Provisions
for adequate combustion and ventilation air must be
provided. Refer to page 8.
WATER VAPOR: A BY-PRODUCT OF UNVENTED
ROOM HEATERS
Water vapor is a by-product of gas combustion. An
unvented room heater produces approximately one (1)
ounce (30ml) of water for every 1,000 BTU's (.3KW's)
of gas input per hour. Refer to page 8.
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
The Vail Premium Vent-Free
Multi-Sided Fireplaces
— Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or
any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppli-
er’s instructions.
If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
WARNING: If the information in these in-
structions are not followed exactly, a fire or ex-
plosion may result causing property damage,
personal injury or loss of life.
Installer: Leave this manual with the appli-
ance.
Consumer: Retain this manual for future refer-
ence.
ANSI Z21.11.2 Gas Fired Decorative Type Unvented Room
Heaters.
GAS-FIRED
Page 1
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - AND OWNER'S MANUAL

INSTALLATION INSTRUCTIONSAND OWNER'S MANUALSEE-THROUGH FIREPLACE MODELS:VFP36SP32EN-1VFP36SP32EP-1PENINSULA FIREPLACE MODELS:VFP36PP32EN-1VFP36

Page 2 - TABLE OF CONTENTS

24309-1-0908Page 10Check all local codes for requirements, especially for the size and type of gas supply line required.Note: Never use plastic pipe.

Page 3 - HARDWARE PACKAGE

24309-1-0908 Page 11CLEARANCESFigure 4a - See Through Fireplace Clearances36”MIN.42”MIN.(CEILING TOTOP OF HOOD)1 3/4” MIN.PERPENDICULARCOMBUSTIBLESIDE

Page 4 - IMPORTANT SAFETY INFORMATION

24309-1-0908Page 12CLEARANCES (cont.)Figure 6a - Mantel Clearances with Standard HoodFigure 6b - Mantel Clearances with Optional Extended HoodMANTELST

Page 5 - LP-GAS WARNING ODOR

24309-1-0908 Page 13Fireplace FramingFraming can be built before or after the fireplace is set in place. Framing should be constructed to accommod

Page 6 - INTRODUCTION

24309-1-0908Page 14Figure 10Fireplace DimensionsFIREPLACE INSTALLATION INSTRUCTIONS (continued)VFP36SP VFP36PPA34 3/4" 34 3/4"B39" 39&q

Page 7 - SPECIFICATIONS

24309-1-0908 Page 15Locating FireplacePlace fireplace in framed opening. Attach the framing brackets to the fireplace and secure to framing. Different h

Page 8 - 24309-1-0908Page 8

24309-1-0908Page 16Extended HoodsIf your non-combustible facing material is over 1" in thickness and will be used to finish this fireplace, extende

Page 9 - (continued)

24309-1-0908 Page 17The fireplace is designed to accept a gas line for connection to the gas valve. Have the line installed by a qualified service pers

Page 10 - GAS SUPPLY

24309-1-0908Page 18Placement of the glowing embers (rockwool) is very individual and light coverage of the areas indicated will provide your best effe

Page 11 - CLEARANCES

24309-1-0908 Page 19Before you begin: Do not handle the logs with your bare hands! Always wear gloves to prevent skin irritation. After handling logs,

Page 12 - COMBUSTIBLE MATERIALS

24309-1-0908Page 2TABLE OF CONTENTSCarton Contents ...

Page 13 - PLANNING INSTALLATION

24309-1-0908Page 201. STOP! Read the safety information label.2. Open bottom louver assembly.3. Set REMOTE/OFF/ON switch to "OFF."4. Tur

Page 14 - 24309-1-0908Page 14

24309-1-0908 Page 21Check the following items during installation prior to lighting the multisided burner:• Check all carryover ports for blockage fr

Page 15 - FIREPLACE OPENING

24309-1-0908Page 22Figure 16 show a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple. The flame wi

Page 16 - INSTALLING HOODS

24309-1-0908 Page 23Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

Page 17 - GAS LINE CONNECTION

24309-1-0908Page 24If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the ga

Page 18 - NAT BURNER - TOP VIEW

24309-1-0908 Page 25WIRING INSTRUCTIONS FOR INSTALLING A DUAL SWITCH / RECEPTACLEIn order to install both the optional Blower and Accent Light ac-cess

Page 19 - 24309-1-0908 Page 19

24309-1-0908Page 26Attention: Install blower assembly before connecting gas in-let supply line.WiringThe appliance, when installed, must be electri

Page 20 - 24309-1-0908Page 20

24309-1-0908 Page 274. Insert blower assembly into interior, bottom of firebox. Note: On peninsula models, the blower must be installed at the

Page 21 - BURNER INSTRUCTIONS

24309-1-0908Page 28WiringThe appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of

Page 22 - PILOT FLAME CHARACTERISTICS

24309-1-0908 Page 29MAINTENANCEKeep the control compartment, logs and burner area surround-ing the logs clean by vacuuming or brushing area at

Page 23 - WIRING DIAGRAM

24309-1-0908 Page 3CARTON CONTENTSFireplace AssemblyLava Rock PackageSoot Warning SheetInstallation Package Rockwool Packet Installation Instruction

Page 24 - TROUBLESHOOTING

24309-1-0908Page 30USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.NOTE: SEE LOG INSTRUCTION MANUAL

Page 25

24309-1-0908 Page 31Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order part

Page 26 - 24309-1-0908Page 26

24309-1-0908Page 32SEE-THROUGH FIREPLACE PARTS VIEW146516891214456812149732242520171831414021232933301922342826NatGas363735274232383924254344454647442

Page 27 - CONTROL SWITCH

24309-1-0908 Page 33PENINSULA FIREPLACE PARTS VIEW14568911101213141516812149732242520171831414021232933301922342826NatGas363735274232383924LP BURNER25

Page 28 - 110 VOLT AC

24309-1-0908Page 34Accessory Description Model NumbersFan Kit12Designed to provide forced air flow. FBB5Variable Speed Control KitWall mounted variab

Page 29 - LK2 ACCENT LIGHT ACCESSORY

24309-1-0908 Page 35Accessory Description Model NumbersAccent Light KitOptional light kit that installs in top of firebox to enhance logset. Operates w

Page 30 - PARTS LIST

24309-1-0908Page 36SERVICE NOTES

Page 31 - HOW TO ORDER REPAIR PARTS

24309-1-0908 Page 37Web Site: www.empirecomfort.comThe Vail Premium Vent-Free FireplacesSEE-THROUGH FIREPLACE MODELS:VFP36SP32EN-1VFP36SP32EP-1PENINSU

Page 32 - 24309-1-0908Page 32

24309-1-0908Page 38Web Site: www.empirecomfort.comThe Vail Premium Vent-Free FireplacesSEE-THROUGH FIREPLACE MODELS: PENINSULA FIREPLACE MODELS:VFP36S

Page 33 - 24309-1-0908 Page 33

24309-1-0908 Page 39Premium Vent-Free Fireplace Framing Dimensions (inches)"A" "B" "C"*Model Framing Height Framing Widt

Page 34 - ACCESSORIES

24309-1-0908Page 4When used without adequate combustion and ventilation air, heater may give off CARBON MONOXIDE, an odorless, poi-sonous gas. Do not

Page 35 - ACCESSORIES (continued)

24309-1-0908Page 40EMPIREEMPIREComfort SystemsEmpire Comfort Systems Inc.918 Freeburg Ave. Belleville, IL 62220If you have a general question about o

Page 36 - SERVICE NOTES

24309-1-0908 Page 5Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smel

Page 37 - 918 Freeburg Avenue

24309-1-0908Page 6Installation on Rugs and TileIf this appliance is installed directly on carpeting, tile or other combustible material othe

Page 38 - VFP36SP32EP-1 VFP36PP32EP-1

24309-1-0908 Page 7ModelVFP36(SP,PP)32EN (NAT) VFP36(SP,PP)32EP (LP)Input Maximum 38,000 38,000Minimum 25,000 30,000Overall DimensionsHeight without

Page 39

24309-1-0908Page 8Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for eve

Page 40 - Comfort Systems

24309-1-0908 Page 9The space in the above example is a confined space because the actual BTU/Hr used is more than the maximum BTU/HR the space can supp

Comments to this Manuals