Empire-comfort-systems BVD36FP32 User Manual

Browse online or download User Manual for Kiln Empire-comfort-systems BVD36FP32. Empire Comfort Systems BVD36FP32 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Page 119400-3-0406
B-VENT
GAS FIREPLACE
MODEL SERIES
MILLIVOLT
BVD34FP30(F,L)N-1
BVD36FP32(F,L)N-1
BVP42FP32(F,L)N-1
DIRECT IGNITION
BVD34FP50(F,L)N-1
BVD36FP52(F,L)N-1
BVP42FP52(F,L)N-1
EFFECTIVE DATE
APRIL 2006
UL FILE NO. MH45034
INSTALLATION INSTRUCTIONS
AND
OWNER’S MANUAL
WARNING: If not installed, operated and maintained
in accordance with the manufacturer’s instructions,
this product could expose you to substances in fuel or
from fuel combustion which can cause death or seri
-
ous illness.
NOT INTENDED FOR USE AS A PRIMARY HEAT
SOURCE. This appliance is tested and approved as
either supplemental room heat or as a decorative
appliance. It should not be factored as primary heat
in residential heating calculations.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified
kit is used.
The Keystone "B" Vent Zero Clearance Gas
Fireplace
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
-
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
-
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbors
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
-
Installation and service must be performed by
a qualified installer, service agency, or the gas
supplier.
GAS-FIRED
Installer: Leave these instructions with the consumer.
Consumer: Retain these instructions for future use.
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - OWNER’S MANUAL

Page 119400-3-0406B-VENTGAS FIREPLACEMODEL SERIESMILLIVOLTBVD34FP30(F,L)N-1BVD36FP32(F,L)N-1BVP42FP32(F,L)N-1DIRECT IGNITIONBVD34FP50(F,L)N-1 BVD36FP5

Page 2 - TABLE OF CONTENTS

Page 10 19400-3-0406Framing dimension "A" includes a three inch clearance for standoffs on firebox. Framing and Finishing 1. Choose

Page 3 - IMPORTANT SAFETY INFORMATION

Page 1119400-3-0406Note: Dimension "C" is the minimum with the fireplace face extending 1/2" in front of the framing to allow for finishi

Page 4 - LP-GAS WARNING ODOR

Page 12 19400-3-0406Vent RunsIn planning the installation for the fireplace, it is necessary to install certain components before the appliance is comp

Page 5 - INTRODUCTION

Page 1319400-3-0406Vent SizeModel BVD34FP series uses a 4" B-Vent for operation.Models BVD36FP and BVP42FP series use a 6" B-Vent f

Page 6 - RIGHT SIDE VIEW

Page 14 19400-3-040614532Before you begin: if you are installing logs into the BVD34 or BVD36 model, then this fireplace is supplied with a set of five

Page 7 - Page 719400-3-0406

Page 1519400-3-0406WARNING: Failure to position the parts in accordance with this diagram or failure to use only parts specifically approved with this

Page 8 - GAS SUPPLY

Page 16 19400-3-0406The OWNER should carefully read and follow these operating instructions at all times. Lower the door assembly to view the gas con

Page 9 - GAS LINE HOLE

Page 1719400-3-0406STANDING PILOT OPERATING INSTRUCTIONS The fireplace is equipped with a 15 foot length of wire that can be used to connect the valve

Page 10 - INSTALLATION

Page 18 19400-3-0406Figure 23THERMOPILEGAS VALVE(OPTIONAL) REMOTE CONTROL RECEIVERDU RECEPTEUR(FACULTATIVE) CONTROLE E DISTANCEWALL SWITCHINTERRUPTEUR

Page 11 - INSTALLATION (CONT)

Page 1919400-3-04061. STOP! Read the safety information above.2. Set wall switch or remote to "OFF."3. Turn off all electric power t

Page 12

Page 2 19400-3-0406Important Safety Information ...3S

Page 13 - VENTING (CONT)

Page 20 19400-3-0406With proper installation and maintenance, your new Gas Fireplace will provide years of trouble-free service. If you do experi-enc

Page 14 - LOG PLACEMENT (5 LOG SET)

Page 2119400-3-0406"B-VENT" FIREPLACESModel Conversion Kit Model (Part Number)BVD34FP3 SERIES BVCK34P (19160)BVD36FP3 SERIES BVCK36P (19161)

Page 15 - LOG PLACEMENT (3 LOG SET)

Page 22 19400-3-0406BURNER ORIFICE CONVERSION - Slope style burners8b. On model BVP42FP3 series fireplaces, you will have a rectangular slop

Page 16 - OPERATING INSTRUCTIONS

Page 2319400-3-0406LED LIGHTLED LUMIÈREBLACK NOIRGREEN VERTWHITE BLANCRED ROUGEBLACK NOIRGAS VALVEVALVE DE GAZ(OPTIONAL) WALL SWITCHINTERRUPTEUR MURAL

Page 17 - OPERATING INSTRUCTIONS (CONT)

Page 24 19400-3-0406A. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than

Page 18 - STANDING PILOT WIRING DIAGRAM

Page 2519400-3-0406With proper installation and maintenance, your new Gas Fireplace will provide years of trouble-free service. If you do experience a

Page 19 - TO TURN OFF GAS TO FIREPLACE

Page 26 19400-3-04061. Turn off the gas supply.2. Turn off the electrical supply to the appliance if so equipped.3. Open or remove glass d

Page 20 - Page 20 19400-3-0406

Page 2719400-3-0406PLEASE NOTEIt is normal for appliances fabricated of steel to give off some expansion and/or contraction noise during the start up

Page 21 - Page 2119400-3-0406

Page 28 19400-3-0406 USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.INDEX NO.PART NUMBER DESCRIPTIONBVD

Page 22

Page 2919400-3-040687654231899101112131415161718192021222324262728b25191718262728a21201529a3031323335a3435b36373839162229b4041DIRECT IGNITION BURNER A

Page 23 - BLACK NOIR

Page 319400-3-0406Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly.• If this appliance is installe

Page 24 - TO TURN OFF GAS TO APPLIANCE

Page 30 19400-3-0406INDEX NO. PART NUMBER PART NUMBER DESCRIPTIONBVP42L BVP42F1 19508 19508 TOP SHIELD2 17247 17247 TOP STANDOFF (2 REQUIRED)3 10554 1

Page 25 - 8" above burner

Page 3119400-3-0406876542318991011121314212229b28a29a302120a3132333435a35b36373839DIRECT IGNITION BURNER ASSEMBLYMILLIVOLT BURNER ASSEMBLY3 PIECE LOG

Page 26 - Maxitrol Valve Conversion

Page 32 19400-3-0406Attention: Install blower assembly before connecting gas inlet supply lineNote: Junction box on right side of fireplace must be

Page 27 - MAINTENANCE AND SERVICE

Page 3319400-3-0406110 VOLT ACJUNCTION BOXWHITESPEEDCONTROLFANSWITCHGROUNDBLACKFAN1 FBB4 BLOWER ASSEMBLY COMPLETE2 R7649 FAN CONTROL3 R4192 SPEED CONT

Page 28 - BVD34 & BVD36 PARTS LIST

Page 34 19400-3-0406CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE BUILDING C

Page 29 - BVD34 & BVD36 PARTS VIEW

Page 3519400-3-0406The following accessory parts can be obtained from your Empire Comfort Systems dealer. If you need additional information beyond wh

Page 30 - BVP42 PARTS LIST

Decorative Louver MissionDecorative Louver ArchDecorative Louver LeafDecorative Frame Rectangle with hingesDecorative Door Leaf RectangleDecorative Do

Page 31 - BVP42 PARTS VIEW

Page 3719400-3-0406Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts

Page 32 - Page 32 19400-3-0406

Page 38 19400-3-0406SERVICE NOTES

Page 33 - 110 VOLT AC

Page 3919400-3-0406SERVICE NOTES

Page 34

Page 4 19400-3-0406Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smel

Page 35 - OPTIONAL ACCESSORIES

Page 40 19400-3-0406Empire Comfort Systems, Inc.918 Freeburg Ave. Belleville, IL 62220PH: 618-233-7420 or 800-851-3153FAX: 618-233-7097 or 800-443-86

Page 36 - DECORATIVE ACCESSORIES

Page 519400-3-0406Instructions to Installer1. Installer must leave instruction manual with owner after installation.2. Installer must have

Page 37 - HOW TO ORDER REPAIR PARTS

Page 6 19400-3-0406Figure 1Dim BVD34 BVD36 BVP42A37"940mm39"990mm43"1092mmB34"864 mm36"914mm40"1,016mmC22 7/8"581mm

Page 38

Page 719400-3-0406Mantel Chart (Figure 3)Figure 3Clearances (Figure 4)Clearance from top front edge of fireplace to ceiling is 36"Clearance from s

Page 39

Page 8 19400-3-0406Figure 6 The gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas

Page 40

Page 919400-3-0406FROM FRONT OFAPPLIANCE TOGAS LINE HOLE3 ½”GAS LINE HOLEBVD34 SERIES - 10”BVD,P (36,42) - 13 ½”Figure 7 BURNER ASSEMBLYREAR TAB (BURN