Empire Comfort Systems CIVF-25-2 Owner's Manual

Browse online or download Owner's Manual for Stoves Empire Comfort Systems CIVF-25-2. Empire Comfort Systems CIVF-25-2 Owner`s manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
INSTALLATION INSTRUCTIONS
AND
OWNER'S MANUAL
CAST IRON
UNVENTED ROOM HEATER
MODEL
CIVF-25-21
WATER VAPOR: A BY-PRODUCT OF UNVENT-
ED ROOM HEATERS
Water vapor is a by-product of gas combustion. An
unvented room heater produces approximately one
(1) ounce (30ml) of water for every 1,000 BTU's
(.3KW's) of gas input per hour. Refer to page 6.
WARNING: If not installed, operated and main-
tained in accordance with the manufacturer's
instructions, this product could expose you to
substances in fuel or from fuel combustion which
can cause death or serious illness.
This is an unvented gas-fired heater. It uses air
(oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventilation
air must be provided. Refer to page 6.
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
The Classic Cast Iron Stoves
— Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or
any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppli-
er’s instructions.
If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
WARNING: If the information in these instruc-
tions are not followed exactly, a fire or explosion
may result causing property damage, personal
injury or loss of life.
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future
reference.
Page 1
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - OWNER'S MANUAL

INSTALLATION INSTRUCTIONSAND OWNER'S MANUALCAST IRON UNVENTED ROOM HEATERMODELCIVF-25-21WATER VAPOR: A BY-PRODUCT OF UNVENT-ED ROOM HEATERSWater

Page 2 - TABLE OF CONTENTS

16938-4-1107Page 10ASSEMBLY OF STOVE CASTINGFigure 6Assembly of Stove Casting (Figures 6, 7, 8, 9, 10, 11 and 12)Attention: Included in the hardware p

Page 3 - IMPORTANT SAFETY INFORMATION

16938-4-1107 Page 11Figure 8 7. Refer to Figure 7, the rear cover has (4) keyholes for attachment to the casting sides. Stand the casting sides on t

Page 4 - LP-GAS WARNING ODOR

16938-4-1107Page 12ASSEMBLY OF STOVE CASTING (continued)Figure 10Figure 1111. Refer to Figure 9, attach casting front to casting by using the (4) ret

Page 5 - SPECIFICATIONS

16938-4-1107 Page 13OPTIONAL STONE INLAY INSTALLATIONWIRE CHANNEL INSTALLATIONThe ON/OFF/REMOTE switch with harness is factory installed into the swit

Page 6 - 16938-4-1107Page 6

16938-4-1107Page 14Before operating this heater, please review the safety warnings pages at the beginning of this manual and those precautions

Page 7 - 16938-4-1107 Page 7

16938-4-1107 Page 15LIGHTING INSTRUCTIONSFOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPL

Page 8 - CLEARANCES

16938-4-1107Page 16PILOT FLAME CHARACTERISTICSFigure 15 shows a correct pilot flame pattern. The correct flame will be blue and will extend beyond the

Page 9 - APPLIANCE HARDWARE PACKAGE

16938-4-1107 Page 17MAIN BURNER FLAME CHARACTERISTICSFigure 18 shows a correct main burner flame pattern. Figure 19 shows an incorrect main burner fla

Page 10 - ASSEMBLY OF STOVE CASTING

16938-4-1107Page 18CIVF-25 ON/OFF/REMOTE SwitchCIVF-25 is equipped with an ON/OFF/REMOTE switch which is located on the wire channel. A wire harness i

Page 11 - 16938-4-1107 Page 11

16938-4-1107 Page 19Wiring Diagram (Figure 21) Figure 21MAINTENANCEIMPORTANT: Turn off gas before servicing appliance. It is recommended that

Page 12 - 16938-4-1107Page 12

16938-4-1107Page 2SECTION PAGEI

Page 13 - WIRE CHANNEL INSTALLATION

16938-4-1107Page 20SYMPTOMS - POSSIBLE CAUSES AND CORRECTIONSIMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning su

Page 14 - OPERATING GUIDELINES

16938-4-1107 Page 21 9. Slight smoke or odor during initial operation.a. Residues from manufacturing processes and logs curing - Problem will stop

Page 15 - LIGHTING INSTRUCTIONS

16938-4-1107Page 22 Index Part No. Number Description Index Part No. Number Description 1 *CI-006 WINDOW RETAINING TAB 2 R-3948 WINDOW

Page 16 - PILOT FLAME CHARACTERISTICS

16938-4-1107 Page 23PARTS VIEW FOR STOVE CASTINGModels: CIFB-1, CIPB-1, CIPG-1, CIPS-1, CIPN-1, CIPR-1

Page 17 - 16938-4-1107 Page 17

16938-4-1107Page 24PARTS VIEW FOR CIVF-25-21

Page 18 - 16938-4-1107Page 18

16938-4-1107 Page 25Installing Optional CIB-2 Blower 1. Loosen, but do not remove, (4) hex-head screws located on the exterior, bottom of the applia

Page 19 - MAINTENANCE

16938-4-1107Page 26CleaningThe blower wheel will collect lint and could require cleaning once a year. If the air output decreases or the noise level i

Page 20 - TROUBLESHOOTING

16938-4-1107 Page 27SERVICE NOTES

Page 21 - HOW TO ORDER REPAIR PARTS

16938-4-1107Page 28Empire Comfort Systems, Inc.918 Freeburg Ave. Belleville, IL 62220PH: 618-233-7420 or 800-851-3153FAX: 618-233-7097 or 800-443-864

Page 22 - PARTS LIST FOR CIVF-25-21

16938-4-1107 Page 3IMPORTANT SAFETY INFORMATION• An unvented room heater having an input rating of more than 6,000 Btu per hour shall not be installe

Page 23 - PARTS VIEW FOR STOVE CASTING

16938-4-1107Page 4SOME POINTS TO REMEMBERNO ODOR DETECTED - ODOR FADELP-GAS WARNING ODORIf a gas leak happens, you should be able to smell the gas bec

Page 24 - PARTS VIEW FOR CIVF-25-21

16938-4-1107 Page 5Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of a

Page 25 - 16938-4-1107 Page 25

16938-4-1107Page 6WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERSPROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIRWater vapor is a by-produc

Page 26 - 16938-4-1107Page 26

16938-4-1107 Page 7Recommended Gas Pipe DiameterPipe Length Schedule 40 PipeInside DiameterTubing, Type L Outside DiameterNat. L.P. Nat. L.P.0-10 feet

Page 27 - SERVICE NOTES

16938-4-1107Page 8CLEARANCESClearances (Figures 2, 3 and 4)When facing the front of the appliance the following minimum clearances to combustible cons

Page 28

16938-4-1107 Page 9APPLIANCE HARDWARE PACKAGEFigure 5Appliance Hardware Package Parts ListPart Description Part NumberQuantity Supplied1/4-20 x 1"