15628-9-1007 Page 27
Figure 36 shows a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple and thermopile.
The flame will surround the thermocouple and thermopile just below the tip. A slight yellow flame may occur where the pilot flame and
main burner flame meet. Figure 37 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple
or thermopile. This will cause the thermocouple or thermopile to cool. When the thermocouple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in Figure 37
See Troubleshooting, page 32.
Figure 38 shows a correct main burner flame pattern. Figure 39
shows an incorrect main burner flame pattern.
If main burner flame pattern is incorrect, as shown in Figure 39
See Troubleshooting, page 32.
Cleaning and Maintenance / Main Burner
Warning: Turn off heater and let cool before cleaning.
After use, cleaning of the main burner may be required for the
proper flame. The main burner may be cleaned by applying air
pressure to the ports on the main burner.
Correct Main Burner Flame
Figure 38
Correct Pilot Flame Pattern
Figure 36
Incorrect Pilot Flame Pattern
Figure 37
PILOT FLAME CHARACTERISTICS