26419-0-0809 Page 3
Countdown Timer
The Countdown Timer Mode allows the control to operate the
unit for up to 3 hours, in 10-minute increments. It can be operated
in either the Manual or Thermostat Modes.
1. To enter Timer Mode, press and release the TIMER button.
The Timer icon will ash.
2. Press the UP or DOWN button to set the running time, in
10-minute increments. Press and release the SET button.
The timer will run for the set time duration.
3. Pressing the TIMER button while in Timer Mode will ter-
minate the Timer operation. The Timer operation will also
terminate if the MODE button is cycled to off.
Thermostat Mode
The unit is placed in Thermostat Mode using the MODE button.
Placing the unit in Thermostat Mode will activate the numbers in
the smaller window on the LCD screen.
1. Press the UP or DOWN button to change the thermostat set
temperature. When the desired set temperature appears, press
and release the SET button to set.
2. If the SET button is not pressed, the set temperature will au-
tomatically be set after 5 seconds.
3. The Thermostat Mode can be de-activated by pressing the
MODE button.
Thermostatic Flame Modulation
This control can perform Main Flame Modulation using the Ther-
mostat. The control will shut the unit off when the room tem-
perature reaches above set temperature. The Thermostat will
automatically modulate the main ame as follows:
2° above set temperature OFF
1° above set temperature Flame Level 1
at set temperature Flame Level 2
1° below set temperature Flame Level 3
2° below set temperature Flame Level 4
3° below set temperature Flame Level 5
4° below set temperature Flame Level 6
5° below set temperature Flame Level 7
Manual Flame Modulation – Main Flame
To change the Flame Level manually, press the FLAME MAIN
button. The current level will show in the MAIN box on the LCD
screen.
1. Press the UP or DOWN button to change the Flame Level.
2. When the unit is turned on, whether in Manual, Thermostatic,
or Program Mode, the Main Flame will automatically ignite
at the High (7) setting. After 5 seconds, the ame will default
to the previous setting.
Manual Flame Modulation – Rear Flame
Not available on all models
To change the Rear Flame Level, press the FLAME REAR
button. The current level will show in the REAR box on the LCD
screen.
1. Press the UP or DOWN button to change the Rear Flame
Level.
2. When the unit is turned on, whether in Manual, Thermostatic,
or Program Mode, the Rear Flame will automatically ignite at
the High (3) setting. After 5 seconds, the ame will default to
the previous setting.
Note: The rear ame level is dependant upon gas ow through
the main valve. Therefore, if the Main Flame setting is less than
high, the rear ame gas ow will be reduced proportionately at
all levels.
Fan Control
The unit must be ON to operate the Fan.
The Fan will turn on after 5 minutes of operation. Once the Fan
comes on, it can be controlled using the FAN button.
1. Press the FAN button, and the fan icon and speed will appear
on the LCD screen.
2. Press the UP or DOWN button to control the fan speed (0-6).
Press the DOWN button until 0 Level is reached to turn the
Fan off.
3. The fan will run for 12 minutes after the unit is shut off in any
mode. The fan may not be controlled during this period.
Accent Light
Not available on all models
The unit does NOT have to be on to operate the lights.
Lights are controlled by the LIGHTS button on the transmitter.
1. Press the LIGHTS button and the light icon and intensity
level will appear on the LCD screen.
2. Press the UP or DOWN button to set the light intensity level.
Press SET, or wait 7 seconds, and the light intensity setting
will be established.
Continuous Pilot
The unit can be changed from Intermittent Pilot Ignition (IPI), to
Continuous, or standing, pilot.
1. To place the unit in continuous pilot mode, press and release
the PROG/TIME and the FLAME MAIN buttons simultane-
ously. Continuous Pilot will appear on the LCD screen.
2. Repeat the simultaneous PROG/TIME and FLAME MAIN
push to place the unit back in IPI mode.
3. This feature can also be activated by the Continuous Pilot
(On/Off) switch on the Main Module.