Empire Comfort Systems VFDR24LBP-1 Owner's Manual

Browse online or download Owner's Manual for Fireplaces Empire Comfort Systems VFDR24LBP-1. Empire Comfort Systems VFDR24LBP-1 Owner`s manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
UNVENTED GAS LOG HEATER
MODELS
VFDR18LB10N-3 VFDR18LB10P-3
VFDR18LBN-2 VFDR18LBP-2
VFDR24LBN-2 VFDR24LBP-2
VFDR30LBN-2 VFDR30LBP-2
VFDT18LBN-2 VFDT18LBP-2
VFDT24LBN-2 VFDT24LBP-2
VFDT30LBN-2 VFDT30LBP-2
VFDM18LBN-2 VFDM18LBP-2
VFDM24LBN-2 VFDM24LBP-2
VFDM30LBN-2 VFDM30LBP-2
VENTED DECORATIVE APPLIANCE
MODELS
VFDR18LB10N-3 VFDR18LB10P-3
VFDR18LBN-2 VFDR18LBP-2
VFDR24LBN-2 VFDR24LBP-2
VFDR30LBN-2 VFDR30LBP-2
VFDM18LBN-2 VFDM18LBP-2
VFDM24LBN-2 VFDM24LBP-2
VFDM30LBN-2 VFDM30LBP-2
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
Vented/Vent-Free Burner and Logs
This is an unvented gas-red heater. It uses air (oxy-
gen) from the room in which it is installed. Provisions
for adequate combustion and ventilation air must be
provided. Refer to page 9.
WARNING: If not installed, operated and maintained
in accordance with the manufacturer's instructions,
this product could expose you to substances in fuel
or from fuel combustion which can cause death or
serious illness.
WATER VAPOR: A BY-PRODUCT OF UN-VENTED
ROOM HEATERS
Water vapor is a by-product of gas combustion. An
unvented room heater produces approximately one (1)
ounce (30ml) of water for every 1,000 BTU's (.3KW's)
of gas input per hour. Refer to page 6.
This appliance may be installed in an aftermarket
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
Do not store or use gasoline or other ammable va-
pors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a neigh-
bors phone. Follow the gas supplier’s instruc-
tions.
If you cannot reach your gas supplier, call the
re department.
Installation and service must be performed by a
qualied installer, service agency or the gas sup-
plier.
WARNING: If the information in this manual are not
followed exactly, a re or explosion may result caus-
ing property damage, personal injury or loss of life.
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
5 Log Set Shown
CERAMIC FIBER LOGS
EMPIRE
EMPIRE
Comfor t Systems
Page 1
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - AND OWNER'S MANUAL

UNVENTED GAS LOG HEATERMODELSVFDR18LB10N-3 VFDR18LB10P-3VFDR18LBN-2 VFDR18LBP-2VFDR24LBN-2 VFDR24LBP-2VFDR30LBN-2 VFDR30LBP-2VFDT18LBN-2 VFDT18LBP-2VF

Page 2 - TABLE OF CONTENTS

27604-2-1210Page 10Mantel Clearances with Hood (Figure 5)       opening. Non-combustible ma

Page 3 - IMPORTANT SAFETY INFORMATION

27604-2-1210 Page 11FOR MASONRY BUILT FIREPLACESFREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING COMBUSTION PRODUCTS FROM DECORATIVE APPLIANCES FOR INS

Page 4 - LP-GAS WARNING ODOR

27604-2-1210Page 12Notice (Damper Clamp Installation)When installing your log set as a vented installation the damper clamp must be used.When insta

Page 5 - INTRODUCTION

27604-2-1210 Page 13Check all local codes for requirements, especially for the size and type of gas supply line required.NOTICE: 

Page 6 - PRODUCT SPECIFICATIONS

27604-2-1210Page 14Before you begin: if you are installing logs onto the VFD(R,T,M)18 or VFD(R,T,M)24 models, this burner assembly is supplied with a

Page 7 - GENERAL INFORMATION

27604-2-1210 Page 15Before you begin: If you are installing logs onto the VFD(R,T,M)30 model, this burner assembly place is supplied with a set of sev

Page 8 - REQUIREMENTS FOR CANADA

27604-2-1210Page 16Flames from the pilot (rear right back side of the pan burner) as i

Page 9 - CLEARANCES

27604-2-1210 Page 17Thermostats are not approved on vented decorative appliances.Label all wires prior to disconnection when servicing controls.

Page 10 - CLEARANCES (continued)

27604-2-1210Page 18WARNING: If you do not follow these instructions exactly, a re or explosion may result causing property dam-age, personal injury o

Page 11 - FIREPLACE PREPARATION

27604-2-1210 Page 19WARNING: If you do not follow these instructions exactly, a re or explosion may result causing property dam-age, personal injury

Page 12 - LOCATIONS

27604-2-1210Page 2TABLE OF CONTENTSImportant Safety Information ...3S

Page 13 - GAS SUPPLY

27604-2-1210Page 20VFDT(18,24,30)LB LIGHTING INSTRUCTIONSWARNING: If you do not follow these instructions exactly, a re or explosion may result causi

Page 14

27604-2-1210 Page 21VFDM(18,24,30)LB LIGHTING INSTRUCTIONSWARNING: If you do not follow these instructions exactly, a re or explosion may result caus

Page 15 - (SHADED AREA ONLY)

27604-2-1210Page 22

Page 16

27604-2-1210 Page 23Figure 25 VFDRFigure 26 VFDT & VFDMAnnual inspection and cleaning by your dealer or qualied service technician is

Page 17 - WIRING - VFDR MODELS ONLY

27604-2-1210Page 24If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backre when lit. If the ga

Page 18 - TO TURN OFF GAS TO APPLIANCE

27604-2-1210 Page 25To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.com. To provid

Page 19

27604-2-1210Page 26Attention: When ordering parts, it is very important that part number and description of part coincide.

Page 20

27604-2-1210 Page 27VFDR SERIES PARTS VIEW1234567891011121413171819202324123456789101112141317181920232412345678910111214151613171819202122232418” BUR

Page 21

27604-2-1210Page 28Attention: When ordering parts, it is very important that part number and description of part coincide.

Page 22 - PILOT FLAME CHARACTERISTICS

27604-2-1210 Page 29123456789101112151617202118” BURNER28242725265 PIECE LOG SET131418192223VFDR18LB10 PARTS VIEW

Page 23 - CLEANING AND SERVICING

27604-2-1210 Page 3WARNINGWhen used without adequate combustion and ventilation air, heater may give off CARBON MONOXIDE, an odorless, poisonous

Page 24 - TROUBLESHOOTING

27604-2-1210Page 30VFDT SERIES PARTS LISTAttention: When ordering parts, it is very important that part number and description of part coincide.

Page 25 - HOW TO ORDER REPAIR PARTS

27604-2-1210 Page 31VFDT SERIES PARTS VIEW272829303233317 PIECE LOG SET32273028295 PIECE LOG SET12345678910111213141718212218” BURNER24” BURNER30” BUR

Page 26 - VFDR SERIES PARTS LIST

27604-2-1210Page 32VFDM SERIES PARTS LISTAttention: When ordering parts, it is very important that part number and description of part coincide.

Page 27 - VFDR SERIES PARTS VIEW

27604-2-1210 Page 33VFDM SERIES PARTS VIEW123456789102312345678910111217231234567891021222318” BURNER 24” BURNER30” BURNER3227302829272829303233315 PI

Page 28 - VFDR18LB10 PARTS LIST

27604-2-1210Page 34To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.com. To provide

Page 29 - VFDR18LB10 PARTS VIEW

27604-2-1210 Page 35APPLIANCE SERVICE HISTORYDate Dealer Name Service Technician Name Service Performed/Notes

Page 30 - VFDT SERIES PARTS LIST

27604-2-1210Page 36EMPIREEMPIREComfor t SystemsEmpire Comfort Systems Inc.918 Freeburg Ave. Belleville, IL 62220If you have a general question about

Page 31 - VFDT SERIES PARTS VIEW

27604-2-1210Page 4Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must nd out if you can smell

Page 32 - VFDM SERIES PARTS LIST

27604-2-1210 Page 5smoke will occur. To prevent triggering of smoke alarms, ve

Page 33 - VFDM SERIES PARTS VIEW

27604-2-1210Page 6PRODUCT SPECIFICATIONSWater vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (3

Page 34

27604-2-1210 Page 7room in which it is installed. Provisions for adequate combustio

Page 35 - APPLIANCE SERVICE HISTORY

27604-2-1210Page 8REQUIREMENTS FOR CANADAThis unit cannot be installed in a UNVENTED application, this unit can only be installed as a

Page 36 - Comfor t Systems

27604-2-1210 Page 9Example of Large Room with 1/2 Wall divider.Figure 1The following formula can be used to determine the maximum heater rating 

Comments to this Manuals

No comments