Empire Comfort Systems VFIL Series Specifications

Browse online or download Specifications for Fireplaces Empire Comfort Systems VFIL Series. Empire Comfort Systems VFIL Series Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Page 1
INSTALLATION INSTRUCTIONS
POWER-VENT
HIGH-EFFICIENCY
FIREPLACE WITH
BAY WINDOW MANTIS MODELS
BF28(B,C,G)M(N,P)-5
BI28(B,C,G)M(N,P)-5
BP28(B,C,G)M(N,P)-5
FIREPLACE MANTIS MODELS
FF28BM(N,P)-3
FI28BM(N,P)-3
FW28BM(N,P)-3
EMPIRE
EMPIRE
Comfort Systems
WARNING
HOT GLASS
DO NOT TOUCH
NEVER
WILL
CAUSE BURNS.
GLASS
UNTIL COOLED.
ALLOW CHILDREN
TO TOUCH GLASS.
WARNING: If not installed, operated and maintained in
accordance with the manufacturers instructions, this
product could expose you to substances in fuel or from
fuel combustion which can cause death or serious ill-
ness.
Attention: Check local codes for venting requirements.
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
WARNING: If the information in these instructions are
not followed exactly, a re or explosion may result
causing property damage, personal injury or loss of
life.
Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call the
re department.
Installation and service must be performed by a
qualied installer, service agency or the gas sup-
plier.
Young children should be carefully supervised when they
are in the same room as the appliance. Toddlers, young
children and others may be susceptible to accidental
contact burns. A physical barrier is recommended if there
are at risk individuals in the house. To restrict access to a
replace or stove, install an adjustable safety gate to keep
toddlers, young children and other at risk individuals out of
the room and away from hot surfaces.
This appliance may be installed in an aftermarket, permanently
located, manufactured home (USA only) or mobile home,
where not prohibited by state or local codes.
This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for use
with other gases, unless a certied kit is used.
Page view 0
1 2 3 4 5 6 ... 51 52

Summary of Contents

Page 1 - INSTALLATION INSTRUCTIONS

Page 1INSTALLATION INSTRUCTIONSPOWER-VENT HIGH-EFFICIENCY FIREPLACE WITH BAY WINDOW MANTIS MODELSBF28(B,C,G)M(N,P)-5BI28(B,C,G)M(N,P)-5BP28(B,C,G)M(N,

Page 2 - TABLE OF CONTENTS

28743-0-0711Page 10Figure 1VENT CLEARANCESUS Installation 1A = Clearance above any grade, veranda, porch or balcony12 in (30 cm)B = Clearance to windo

Page 3 - IMPORTANT SAFETY INFORMATION

28743-0-0711 Page 11VENTING REQUIREMENTSWARNINGThis appliance must not be vented with any other ap-pliances, even if that appliance is of the condensi

Page 4 - SOME POINTS TO REMEMBER

28743-0-0711Page 12VENT EXAMPLES FOR SINGLE FLUEFigure 3 displays a single ue (one-pipe) installation. Because the distance from the heater to the r

Page 5

28743-0-0711 Page 13DIRECT VENT AND COLINEAR VENT EXAMPLESFigure 5 displays a two-pipe installation. Because the distance from the heater to t

Page 6 - INTRODUCTION

28743-0-0711Page 14DIRECT VENT AND COLINEAR VENT EXAMPLESCOLINEAR ADAPTER12” MINIMUM TO GRADERECOMMENDED 12” MINIMUM TOMAXIMUM EXPECTED SNOW LEVELREAR

Page 7

28743-0-0711 Page 15COLINEAR TRANSITION VENT KITThe Colinear Transition Kit (Part number PVCT) is available and can be used to secure the ue and

Page 8 - ed service person

28743-0-0711Page 16ROUGH FRAMING DIMENSIONSABCACCESSPANELSFigure 16ACCESSPANELSFigure 17Single VentDirect Vent and Colinear VentCoaxial Vent Flex Vent

Page 9 - GAS SUPPLY

28743-0-0711 Page 17INSERT INTO MASONRY FIREPLACEFigure 18Single VentDirect Vent and Colinear VentFlex VentBay Window Mantis with PV-4HShort Top Cover

Page 10 - VENT CLEARANCES

28743-0-0711Page 18BAY WINDOW MANTIS CLEARANCE TO COMBUSTIBLESFreestanding ClearancesA Rear Wall to Heater 2” (1-1/4” for coaxial venting)B Side Wall

Page 11 - VENTING REQUIREMENTS

28743-0-0711 Page 19FIREPLACE MANTIS CLEARANCE TO COMBUSTIBLESInsert ClearancesA Rear Wall to Heater 2” (1-1/4” for coaxial venting)B Side Wall to Hea

Page 12 - VENT EXAMPLES FOR SINGLE FLUE

28743-0-0711Page 2TABLE OF CONTENTSImportant Safety Information ...

Page 13 - Note: Exhaust must be a

28743-0-0711Page 20BAY WINDOW MANTIS SPECIFICATIONS28”33-3/4”8-5/8”17-5/8”12-1/4”OPTIONAL PEDESTAL(MUST BE INSTALLED ONHEATER PRIOR TO APPLIANCEINSTAL

Page 14 - PVC CEMENT

28743-0-0711 Page 2135-7/16”OR38”LOUVER29-3/4”5-15/16”23-13/16”10-1/8”6-13/16”PV-4H(SHORTTOPCOVER KIT)3-9/16”16-15/16”BAY WINDOW MANTIS SPECIFICATIONS

Page 15 - VENT ADAPTOR KITS

28743-0-0711Page 2235”33-7/16”35”29-3/8”Heater In Wall - 35 Inch Picture Frame Surround FWK28(BL,CM,HP,SS) - Contains surround, hood, and lower frontH

Page 16 - ROUGH FRAMING DIMENSIONS

28743-0-0711 Page 23FIREPLACE MANTIS SPECIFICATIONS38”30-7/8”FLUEOUTLETAIR INLETELECTRICCORDFLEX HOSEOPENING1-1/8”7-5/16”4-3/16”2-5/8”6-1/8”3-9/16”13/

Page 17 - INSERT INTO MASONRY FIREPLACE

28743-0-0711Page 24GAS CONNECTION INSTALLATIONPUSH IN PLUGACCESS PLATECAUTIONThe gas supply line to the heater must be installed under conditi

Page 18

28743-0-0711 Page 25BAY WINDOW MANTIS LOG SET INSTALLATION INSTRUCTIONSLog InstallationPositioning of the logs is critical to the safe and clean opera

Page 19

28743-0-0711Page 26FIREPLACE MANTIS LOG SET INSTALLATION INSTRUCTIONSLog InstallationPositioning of the logs is critical to the safe and clean operati

Page 20

28743-0-0711 Page 27WIRINGThis appliance is equipped with a three-prong [grounding] plug for your protection against shock hazard and should be

Page 21 - 2-13/16”

28743-0-0711Page 28START UP CHECK LIST1. Verify the gas line service does not exceed 10.5 in. w.c. and is not below 5.0 in. w.c. for

Page 22 - 33-7/16”

28743-0-0711 Page 29LIGHTING INSTRUCTIONSFOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLO

Page 23

28743-0-0711 Page 3IMPORTANT SAFETY INFORMATIONTHIS IS A HEATING APPLIANCEWARNINGThis appliance must be installed and repaired by a qualied

Page 24 - GAS CONNECTION INSTALLATION

28743-0-0711Page 30START UP AND ADJUSTMENTSA. With main electrical power to the heater turned off, install 4 AA sized 1.5V batteries into the rem

Page 25

28743-0-0711 Page 31START UP AND ADJUSTMENTSSequence of Operations – One Burner Only1. The Display Panel will be energized, and the light for either

Page 26

28743-0-0711Page 32FRBTC REMOTE INSTRUCTIONSINTRODUCTIONThis remote control system was developed to provide a safe, reliable and user-friendly remote

Page 27

28743-0-0711 Page 33SETTING °F / °C SCALEThe factory setting for temperature is °F. To change this setting to °C, rst• Press the ON key and the OFF

Page 28 - START UP CHECK LIST

28743-0-0711Page 34OPERATIONAL NOTES:The Thermo Feature on the transmitter operates the appliance whenever the ROOM TEMPERATURE varies a cer

Page 29 - LIGHTING INSTRUCTIONS

28743-0-0711 Page 35CP (CHILDPROOF) FEATUREThis ECS remote control includes a CHILDPROOF “LOCK-OUT” feature that allows the user to “LOCK-OUT” operati

Page 30 - START UP AND ADJUSTMENTS

28743-0-0711Page 36THERMO- SAFETY FEATURE – RECEIVER (T/S –RX)This ECS remote control has a THERMO- SAFETY feature that is built into the system’s REC

Page 31

28743-0-0711 Page 37BATTERY LIFELife expectancy of the alkaline batteries in the transmitter should be at least 12 months. Check and replace all batte

Page 32 - FRBTC REMOTE INSTRUCTIONS

28743-0-0711Page 38AUTOMATIC HUMIDIFIER OPERATIONThe Mantis Power-Vent High-Efciency Fireplace has an auto-matic humidier designed into the h

Page 33

28743-0-0711 Page 39Economy Mode (Red Button Operation)To utilize this feature, a programmable control or thermostat must be connected to the heat

Page 34

28743-0-0711Page 4SAFETY INFORMATION FOR USERS OF LP-GASLP-Gas (Propane) is a ammable gas which can cause res and explosions. In its natural state,

Page 35

28743-0-0711Page 40MAINTENANCE & SERVICEThe Mantis should be inspected and serviced annually by a quali-ed service person. This will ensure that

Page 36

28743-0-0711 Page 41MAINTENANCE & SERVICEOver Temperature Limit SwitchThe Mantis Power-Vent High-Efciency Fireplace is protected against o

Page 37

28743-0-0711Page 42BAY WINDOW MANTIS PARTS LISTINDEX NO.PART NO.DESCRIPTION1 27072 REAR PANEL ASSEMBLY2 21654 BRACKET, PIPE ASSEMBLY3 24831 REAR HEAT

Page 38

28743-0-0711 Page 43BAY WINDOW MANTIS PARTS LIST50 26128 GAS LINE - FRONT51 M174 GASKET52 11269 GAS LINE BRACKET53 R8886 COMPRESSION FITTING54 R8812 V

Page 39 - OPTIONAL CONTROLS

28743-0-0711Page 44BAY WINDOW MANTIS PARTS VIEW14A324B4C5697302852127242819111293416142625221781336183523159493

Page 40 - MAINTENANCE & SERVICE

28743-0-0711 Page 45BAY WINDOW MANTIS PARTS VIEW696732615047485354535160205655484780523940414238454689858687888184787776904443493782707164796362575930

Page 41

28743-0-0711Page 46FIREPLACE MANTIS PARTS LISTINDEX NO.PART NO.DESCRIPTION1 25207 PANEL - TOP2 21595 CONDENSATE TRAY3 25223 LOUVER - TOP4 25212 REAR B

Page 42 - BAY WINDOW MANTIS PARTS LIST

28743-0-0711 Page 47FIREPLACE MANTIS PARTS LIST52 R10182 WIRE HARNESS - 120V53 R10190 WIRE HARNESS - 12V SMALL54 R10183 WIRE HARNESS - 12V LARGE55 R88

Page 43

28743-0-0711Page 48FIREPLACE MANTIS PARTS VIEW62696465636866671234567891112131415161819602021222324255354555852282930313261373959404448457547504942414

Page 44 - BAY WINDOW MANTIS PARTS VIEW

28743-0-0711 Page 49To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.com. To provid

Page 45

28743-0-0711 Page 5REQUIREMENTS FOR MASSACHUSETTSFor all side wall horizontally vented gas fueled equipment installed in every dwelling, building or s

Page 46 - FIREPLACE MANTIS PARTS LIST

28743-0-0711Page 50WARRANTY TERMS Purchase Date: Dealer Name/Phone:Empire Comfort Systems Inc. warrants this hearth product to be free from defects

Page 47

28743-0-0711 Page 51APPLIANCE SERVICE HISTORYDate Dealer Name Service Technician Name Service Performed/Notes

Page 48 - FIREPLACE MANTIS PARTS VIEW

28743-0-0711Page 52EMPIREEMPIREComfor t SystemsEmpire Comfort Systems Inc.918 Freeburg Ave. Belleville, IL 62220If you have a general question about

Page 49 - HOW TO ORDER REPAIR PARTS

28743-0-0711Page 6INTRODUCTIONWARNINGThe safety information listed below must be followed during the installation, service, and operation of this pr

Page 50 - WARRANTY TERMS

28743-0-0711 Page 7Bay Window Mantis Models B(F,I,P)28(B,C,G)M(N,P)Input BTU/HR (KW/H) 19,000 Rear - 9,000 FrontHeight 25-1/4”Width 28”Depth 17-5/8”G

Page 51 - APPLIANCE SERVICE HISTORY

28743-0-0711Page 8INSTALLATION AND GENERAL SAFETY INFORMATIONGeneral InformationThis series is designed certied in accordance with American Na-tional

Page 52 - Comfor t Systems

28743-0-0711 Page 9GAS SUPPLYAll gas piping must be installed in compliance with local codes and utility regulations. In the absence of local c

Comments to this Manuals

No comments