32274-8-0115 Page 13
FIREPLACE FRAMING AND INSTALLATION
Figure 12
Alternate Framing and Installation Method
1. Installangesonsideofreplaceasshownusingholeson
sideofrebox.SeeFigure9.Themiddlepairofholesiffor
the 1/2 inch non-combustible board provided with the unit.
2. Connect the side framing studs to the top stud as shown in
Figure 13. The channel of the studs should face inward.
The replace is designed to accept a 3/8-inch gas line for an
approvedventlessgaslogset.Havethelineinstalledbyaqualied
service person in accordance with all building codes. Consult local
building codes to properly size the gas supply line leading to the 3/8-
inchhook-upattheunit.ThestateofMassachusettsrequiresthat
aexibleapplianceconnectorcannotexceedthreefeetinlength.
Aex-lineandshut-offvalvehavebeenprovided.The gas shut-off
valve must be located outside of the unit in an accessible area.
Checkgastype.Useonlythe gastypeindicatedonthegaslog
set rating plate. If the gas listed on the plate is not your type of gas
supply, DO NOT INSTALL. Contact your dealer for proper model.
AlwaysuseanexternalregulatorforallLPreplacestoreducethe
supplytankpressuretoamaximumof14"w.c.Thisisinaddition
totheregulatorttedtothelogset.
WARNING: CONNECTION DIRECTLY TO AN UNREGULATED
L.P. TANK CAN CAUSE EXPLOSION.
Install only a ANSI Z21.97.1/CSA 2.41 ventless log set into this
replace.
GAS LINE CONNECTION
Figure 13
3. Connecttheframingstudstotheangesusingfour#10pan-
head screws.
Note: If using a drain tray, the bottom of the side framing studs
willbeapproximately1”fromthebottomoftherebox.
4. Locatethemiddlebracket.Loosenthescrewinthemiddle
topofthereplace.Slidethebracketunderthescrewas
shown in Figure 11. Tighten the hex-head screws on the
replacesecureapan-headscrewthroughthemiddle
bracketandintothetopstud.
5. Locate the two non-combustible boards and place them
abovethereplaceasshowninFigure12.Attachthe
non-combustibleboardtothestudswithsix10-16athead
screws.
6. Securethenon-combustibleboardtothemiddlebracket
usingtwo10-16atheadscrewsasshowninFigure12.
7. Movethereplaceintoposition.Connectthegaslinetothe
unitandcheckforleakswithasoapywatersolution.
Note: Ensure that the gas shut-off valve is accessible.
8. Securereplacetoframingoroor.