32274-8-0115Page 16
Ifpilotamepatternisincorrect
• SeeTroubleshooting,page16.
Main Burner Flame Pattern
Themainburneramewillbecompletelyyellow.
Main Burner Flame Ignition and Extinction
Whenthemainburnerisigniteditwilltakeafewsecondsforthefullamepatterntodevelop.
Whenthemainburnerisextinguisheditwilltakeafewsecondsfortheamestodisappear.Itisnormaltohavetheamesburndown
near the burner, as the remaining gas is burned.
MAIN BURNER FLAME CHARACTERISTICS
Label all wires prior to disconnection when servicing controls. Wiring
errors can cause improper and dangerous operation. Verify proper
operation after servicing.
1. Removebatteries(4)andbatterypackfrominstructionenve-
lopepackage.
2. Slidebatterycoverplateoffofbatterypack,insertbatteries
(ensure correct polarity), and replace battery cover plate.
3. Connectredwirefrombatterypacktoredwirefromvalve.
WIRING
MAIN
PILOT
Learn
MOTOR COMM.
POWER
IPI
Continuous
Pilot
Off/On
Remote/Off
S I
ADJ.
(GND)
HI/LO
Solenoid
ORANGE
(IGNITOR)
BLACK
(SENSOR)
BLACK
ORANGE
GREEN
WHITE
BROWN
PILOT
GAS CONTROL
VALVE
ELECTRONIC
CONTROL MODULE
AF-4000 B/P
RED
BLACK
BLACK
BROWN
RED
ORANGE
N/A
CUSTOMER PROVIDED
WALL SWITCH
4. Connectblackwirefrombatterypacktoredwirefromvalve.
5. Attachwireharnessfromcontrolmoduletobatterypack.
6. Placebatterypackonraisedsectionofreboxbottom
through hole in burner bottom.
Note:Thereplacemaybeoperatedwithouttheremoteby
connecting the brown control module wires to a wall switch. The
remote/off switch on the control module must be in the "OFF"
position.